Victron RJ45 UTP Cable 0.3m - ASS030064901

Victron RJ45 UTP Cable 0.3m - ASS030064901

$5.51
Sale price  $5.51 Regular price  $7.65
Skip to product information
Victron RJ45 UTP Cable 0.3m - ASS030064901

Victron RJ45 UTP Cable 0.3m - ASS030064901

$5.51
Sale price  $5.51 Regular price  $7.65

Genuine Victron communication cable

Victron Energy RJ45 UTP Cable 0.3m | Part # ASS030064901

A genuine Victron Energy RJ45 cable for short, clean VE.Bus and VE.Can communication links.

The Victron RJ45 UTP Cable 0.3m, Epoch SKU ASS030064901, is a compact Victron Energy RJ45 cable built for reliable data communication between supported VE.Bus, VE.Can, control, interface, and GX components. At only 0.3 meters—approximately 11.8 inches—this 0.3 meter Victron cable is ideal for clean solar wiring boards, tightly mounted RV and marine power systems, and adjacent Victron components where excess cable creates clutter.

0.3m
Cable length
11.8 in
Approx. length
RJ45
Connector type
UTP
Cable construction
VE.Bus
Supported use
VE.Can
Supported use

Flawless Communication for Victron & Epoch Systems

Reliable system data begins with the correct cable and documented pinout.

Advanced inverter, charger, monitoring, and battery systems depend on consistent communication to report status and coordinate operation. This genuine Victron RJ45 UTP cable provides a short, straight-through connection for documented Victron network applications, reducing excess cable and helping installers keep communication wiring separate, organized, and easy to service.

The cable uses the familiar RJ45 connector format, but it should only be installed in ports and systems that specifically call for a standard RJ45 UTP cable. Battery CAN connections are model-specific, and some managed batteries require a special Type A, Type B, or manufacturer-supplied communication harness instead.

Perfect for VE.Bus & VE.Can Networks

Use this VE.Bus communication cable for documented MultiPlus, Quattro, control-panel, MK3-USB, and GX connections. It can also serve as a VE.Can network cable between compatible devices when their manuals specify a standard straight-through RJ45 UTP cable. VE.Can networks require the correct terminators at both ends.

0.3 Meters for Clean, Tangle-Free Wiring

At approximately 11.8 inches long, this short RJ45 cable is purpose-built for components mounted close together. It minimizes coils, makes service loops easier to control, and keeps compact solar, RV, marine, and battery-system wiring boards professional and readable.

Why Choose a Genuine Victron RJ45 Cable?

Correct straight-through wiring and manufactured connector quality simplify troubleshooting.

Exact Victron part identification Epoch lists this cable as ASS030064901, making it easy to verify the intended accessory before installation.
Ultra-short 0.3m length Approximately 11.8 inches keeps side-by-side components connected without large coils of unused cable.
Standard RJ45 UTP format Uses a straight-through unshielded twisted-pair layout for documented Victron communication networks.
VE.Bus compatible Suitable for supported VE.Bus device links, control panels, interfaces, and GX connections.
VE.Can compatible Suitable for standard VE.Can links when the connected equipment manual calls for RJ45 UTP.
Positive-latching connectors RJ45 plugs click into supported ports for a clean, removable communication connection.
Clean wiring-board layout Ideal for tightly organized RV, marine, solar, and off-grid electrical installations.
Manufactured cable reliability Victron recommends manufactured cables to reduce difficult-to-diagnose communication issues caused by poor crimps or incorrect wiring.

UTP Reliability for Communication Networks

UTP means Unshielded Twisted Pair. The twisted conductor pairs help preserve data integrity in supported Victron communication networks. Victron advises using manufactured cables because incorrect pinouts and poor field crimps can produce intermittent, difficult-to-diagnose communication faults.

Plug-and-Play Simplicity

RJ45 plugs on both ends allow quick installation into compatible ports without cutting or crimping. Confirm the port label, network type, speed, termination requirements, and device manual before powering or commissioning the system.

Compatible applications

Short communication links for compact Victron electrical systems.

  • Connect compatible MultiPlus or Quattro VE.Bus equipment to a Cerbo GX or other supported GX device.
  • Link multiple compatible VE.Bus devices in documented parallel, split-phase, or three-phase configurations.
  • Connect Digital Multi Control, Phoenix Inverter Control, or a compatible inverter control panel.
  • Connect an MK3-USB or other supported VE.Bus interface for configuration and service work.
  • Create a short VE.Can connection between adjacent Victron devices when the device manuals specify standard RJ45 UTP.
  • Keep compact RV, marine, solar, and off-grid electrical boards clean with minimal excess cable.
  • Daisy-chain compatible Epoch V2 or V2-T batteries only where the exact battery manual specifies a standard straight-through RJ45 cable for the battery-to-battery link.

Technical specifications

Exact part identification, length, connector format, and supported network uses.

Cable specifications and compatibility
Manufacturer Victron Energy
Epoch product title Victron RJ45 UTP Cable 0.3m - ASS030064901
Epoch SKU / part number ASS030064901
Current Victron 2026 price-list reference ASS030064900 for the 0.3m version; verify the exact label if procurement matching is critical
Length 0.3 meters / approximately 11.8 inches / just under 1 foot
Cable type UTP — Unshielded Twisted Pair data cable
Connector type RJ45 plug to RJ45 plug
Wiring format Standard straight-through RJ45 UTP
Primary network uses VE.Bus and VE.Can; legacy VE.Net only where the device documentation supports it
Victron control/interface uses Digital Multi Control, Phoenix Inverter Control, MK3-USB / compatible interfaces
GX device use Documented VE.Bus or VE.Can connection to compatible GX equipment
VE.Can termination Terminate both ends of the VE.Can network with the proper VE.Can terminators
VE.Bus termination Do not install VE.Can terminators in unused VE.Bus ports
Battery CAN compatibility Model-specific — verify the battery pinout and manual before using a standard UTP cable
Electrical function Data and communication only; not a battery, charger, AC, or DC power cable

Related Victron system components

Common companion items for communication and system setup.

Victron Cerbo GX or compatible GX monitoring device.
Victron MK3-USB interface for VE.Bus configuration and service.
Victron VE.Can RJ45 terminators for properly terminated VE.Can networks.
Victron VE.Can-to-CAN-bus BMS Type A or Type B cable when the managed-battery documentation requires a special pinout.
Longer Victron RJ45 UTP cables when components are mounted farther than 0.3 meters apart.

Confirm the network before connecting

RJ45 is a connector shape—not a guarantee of identical pinout or protocol.

Identify whether the connection is VE.Bus, VE.Can, BMS-Can, CAN-bus BMS, legacy VE.Net, or a manufacturer-specific battery link. Configure the correct GX CAN profile, install terminators where required, and follow the connected equipment manuals before commissioning the system.

Frequently asked questions

Victron RJ45 UTP Cable 0.3m FAQs

Common questions about part number, cable length, VE.Bus, VE.Can, Cerbo GX, and battery communication.

What is the Victron ASS030064901 RJ45 cable used for?

This 0.3-meter Victron RJ45 UTP cable is a short data and communication cable for documented Victron connections. Common uses include VE.Bus links between compatible MultiPlus or Quattro devices, connections to a GX device, Digital Multi Control or Phoenix Inverter Control connections, and an MK3-USB interface. It can also be used for standard VE.Can links when the connected device manuals call for a straight-through RJ45 UTP cable.

How long is 0.3 meters?

0.3 meters is approximately 11.8 inches, or just under 1 foot. The short length is ideal for devices mounted side by side on a compact electrical board, inside a rack, or within the same battery and inverter compartment.

Can I use a standard computer Ethernet cable instead?

A correctly wired, straight-through RJ45 UTP cable may appear physically similar, but Victron recommends manufactured cables to reduce communication problems caused by crossover wiring, poor crimps, broken conductors, or inconsistent connector quality. The genuine Victron part also makes cable identification and troubleshooting easier.

Does this cable connect an Epoch battery directly to a Victron Cerbo GX?

Only when the exact Epoch battery manual specifies a standard straight-through RJ45 UTP cable for that connection. Some Epoch V2 and V2-T systems use standard RJ45 cables between batteries but use a supplied grey communication harness or a model-specific CAN cable at the GX device. Other managed batteries require a Victron VE.Can-to-CAN-bus BMS Type A, Type B, or manufacturer-specific cable. Verify the battery manual before connecting it.

Is this a straight-through or crossover cable?

This product is a standard straight-through RJ45 UTP cable for the Victron applications listed by the manufacturer. Do not substitute a crossover cable, because a crossover pinout can cause communication faults or prevent connected equipment from being detected.

Do I need a VE.Can terminator with this cable?

VE.Can networks must be terminated at both ends with the correct VE.Can terminators. VE.Bus connections are different: unused VE.Bus ports should generally remain open and should not receive blue VE.Can terminators. Follow the manual for the exact device and network type.

Can this cable carry battery or inverter power?

No. This is a low-voltage data and communication cable. It is not a battery interconnect, charger cable, AC power cable, or DC current-carrying cable. Use properly sized power conductors for all battery and inverter connections.

What is the difference between ASS030064901 and ASS030064900?

Epoch currently lists this product under SKU ASS030064901. Victron’s current 2026 price list identifies the 0.3-meter RJ45 UTP cable as ASS030064900. This may reflect a seller, regional, packaging, or revision suffix. If exact part-number matching is required for procurement, confirm the label with Epoch or Victron before ordering.

You may also like